From Initiator Switch:
G620_82_Top:FID128:admin> nsshow -t
{
Type Pid COS PortName NodeName TTL(sec)
N 010000; 3;21:00:00:24:ff:17:ab:4c;20:00:00:24:ff:17:ab:4c; na
FC4s: FCP NVMe
NodeSymb: [48] "QLE2742 FW:v8.06.43 DVR:v10.00.01.04.13-k-u4-dt2"
Fabric Port Name: 20:00:c4:f5:7c:16:4b:84
Permanent Port Name: 21:00:00:24:ff:17:ab:4c
Device type: Physical Initiator
Port Index: 0
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 010100; 3;21:00:00:24:ff:91:9b:05;20:00:00:24:ff:91:9b:05; na
FC4s: FCP NVMe
NodeSymb: [48] "QLE2692 FW:v8.06.43 DVR:v10.00.01.04.13-k-u4-dt2"
Fabric Port Name: 20:01:c4:f5:7c:16:4b:84
Permanent Port Name: 21:00:00:24:ff:91:9b:05
Device type: Physical Initiator
Port Index: 1
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 16G
N 010200; 3;10:00:00:10:9b:1c:0f:6e;20:00:00:10:9b:1c:0f:6e; na
FC4s: FCP NVMe
PortSymb: [1] "0"
NodeSymb: [86] "Emulex LPe32002-M2 FV11.4.216.0 DV11.4.220.2. HN:G8-69-92-16-SP3-6E-32c-INI. OS:Linux."
Fabric Port Name: 20:02:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:00:10:9b:1c:0f:6e
Device type: Physical Initiator
Port Index: 2
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 010800; 3;10:00:14:02:ec:ec:4d:e6;20:00:14:02:ec:ec:4d:e6; na
FC4s: FCP NVMe
PortSymb: [34] "Emulex PPN-10:00:14:02:EC:EC:4D:E6"
NodeSymb: [76] "Emulex SN1600E2P FV11.4.220.0 DV11.4.204.8 HN:RACK103-S13 OS:Windows 2012 R2"
Fabric Port Name: 20:08:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:14:02:ec:ec:4d:e6
Device type: Physical Initiator
Port Index: 8
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Slow Drain Device: Yes
Device link speed: 32G
N 010c00; 3;10:00:14:02:ec:ec:4d:d3;20:00:14:02:ec:ec:4d:d3; na
FC4s: FCP NVMe
PortSymb: [1] "1"
NodeSymb: [66] "Emulex SN1600E2P FV11.4.220.0 DV11.4.220.9. HN:R105-S01. OS:Linux."
Fabric Port Name: 20:0c:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:14:02:ec:ec:4d:d3
Device type: Physical Initiator
Port Index: 12
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011300; 3;10:00:00:90:fa:c7:fe:88;20:00:00:90:fa:c7:fe:88; na
FC4s: FCP NVMe
PortSymb: [34] "Emulex PPN-10:00:00:90:FA:C7:FE:88"
NodeSymb: [82] "Emulex LPe32002-M2 FV11.4.216.0 DV11.4.204.8 HN:WIN-195F648TJ0R OS:Windows 2012 R2"
Fabric Port Name: 20:13:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:00:90:fa:c7:fe:88
Device type: Physical Initiator
Port Index: 19
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011900; 3;51:40:2e:c0:01:17:90:36;51:40:2e:c0:01:17:90:37; na
FC4s: FCP
PortSymb: [64] "QLogic Port1 WWPN 51:40:2e:c0:01:17:90:36......................."
NodeSymb: [33] "SN1600Q FW:v8.05.61 DVR:v9.2.6.20"
Fabric Port Name: 20:19:c4:f5:7c:16:4b:84
Permanent Port Name: 51:40:2e:c0:01:17:90:36
Device type: Physical Initiator
Port Index: 25
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011a00; 3;51:40:2e:c0:01:7c:ab:70;51:40:2e:c0:01:7c:ab:71; na
FC4s: FCP
PortSymb: [64] "QLogic Port0 WWPN 51:40:2e:c0:01:7c:ab:70......................."
NodeSymb: [33] "SN1600Q FW:v8.05.61 DVR:v9.2.4.21"
Fabric Port Name: 20:1a:c4:f5:7c:16:4b:84
Permanent Port Name: 51:40:2e:c0:01:7c:ab:70
Device type: Physical Initiator
Port Index: 26
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011b00; 3;10:00:14:02:ec:ec:4d:de;20:00:14:02:ec:ec:4d:de; na
FC4s: FCP
PortSymb: [34] "Emulex PPN-10:00:14:02:EC:EC:4D:DE"
NodeSymb: [76] "Emulex SN1600E2P FV11.4.220.0 DV11.4.204.8 HN:RACK108-S22 OS:Windows 2012 R2"
Fabric Port Name: 20:1b:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:14:02:ec:ec:4d:de
Device type: Physical Initiator
Port Index: 27
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011d00; 3;10:00:14:02:ec:ec:7d:9b;20:00:14:02:ec:ec:7d:9b; na
FC4s: FCP
PortSymb: [34] "Emulex PPN-10:00:14:02:EC:EC:7D:9B"
NodeSymb: [76] "Emulex SN1600E2P FV11.4.220.0 DV11.4.204.8 HN:RACK103-S15 OS:Windows 2012 R2"
Fabric Port Name: 20:1d:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:14:02:ec:ec:7d:9b
Device type: Physical Initiator
Port Index: 29
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011e00; 3;51:40:2e:c0:01:17:90:90;51:40:2e:c0:01:17:90:91; na
FC4s: FCP
PortSymb: [64] "QLogic Port0 WWPN 51:40:2e:c0:01:17:90:90......................."
NodeSymb: [33] "SN1600Q FW:v8.05.61 DVR:v9.2.4.21"
Fabric Port Name: 20:1e:c4:f5:7c:16:4b:84
Permanent Port Name: 51:40:2e:c0:01:17:90:90
Device type: Physical Initiator
Port Index: 30
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 011f00; 3;10:00:14:02:ec:ec:6d:66;20:00:14:02:ec:ec:6d:66; na
FC4s: FCP
PortSymb: [34] "Emulex PPN-10:00:14:02:EC:EC:6D:66"
NodeSymb: [76] "Emulex SN1200E2P FV11.4.220.0 DV11.4.204.8 HN:RACK108-S22 OS:Windows 2012 R2"
Fabric Port Name: 20:1f:c4:f5:7c:16:4b:84
Permanent Port Name: 10:00:14:02:ec:ec:6d:66
Device type: Physical Initiator
Port Index: 31
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 16G
N 012000; 3;51:40:2e:c0:00:ba:94:ec;51:40:2e:c0:00:ba:94:ed; na
FC4s: FCP
NodeSymb: [30] "84Q FW:v8.02.00 DVR:v9.1.17.25"
Fabric Port Name: 20:20:c4:f5:7c:16:4b:84
Permanent Port Name: 51:40:2e:c0:00:ba:94:ec
Device type: Physical Initiator
Port Index: 32
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 8G
N 012400; 3;51:40:2e:c0:01:17:90:b4;51:40:2e:c0:01:17:90:b5; na
FC4s: FCP
NodeSymb: [34] "SN1600Q FW:v8.05.61 DVR:v9.1.17.25"
Fabric Port Name: 20:24:c4:f5:7c:16:4b:84
Permanent Port Name: 51:40:2e:c0:01:17:90:b4
Device type: Physical Initiator
Port Index: 36
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
The Local Name Server has 14 entries }
G620_82_Top:FID128:admin>
From Target Switch:
G620_81_Bottom:FID128:admin> nsshow -t
{
Type Pid COS PortName NodeName TTL(sec)
N 021900; 3;20:21:00:02:ac:01:9f:21;2f:f7:00:02:ac:01:9f:21; na
FC4s: FCP
PortSymb: [29] "MXN6092BKH - 0:2:1 - LPE32002"
NodeSymb: [36] "HPE_3PAR 8200 - MXN6092BKH - fw:3310"
Fabric Port Name: 20:19:c4:f5:7c:16:a3:a0
Permanent Port Name: 20:21:00:02:ac:01:9f:21
Device type: Physical Target
Port Index: 25
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 021a00; 3;20:21:00:02:ac:01:21:e0;2f:f7:00:02:ac:01:21:e0; na
FC4s: FCP
PortSymb: [26] "1674208 - 0:2:1 - LPE16002"
NodeSymb: [32] "HP_3PAR 7200 - 1674208 - fw:3223"
Fabric Port Name: 20:1a:c4:f5:7c:16:a3:a0
Permanent Port Name: 20:21:00:02:ac:01:21:e0
Device type: Physical Target
Port Index: 26
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 16G
N 021b00; 3;10:00:00:90:fa:c7:d9:37;20:00:00:90:fa:c7:d9:37; na
FC4s: NVMe
PortSymb: [1] "0"
NodeSymb: [85] "Emulex LPe32002-M2 FV11.4.216.0 DV11.4.220.2. HN:G8-63-50-5-SP3-37-32c-TGT. OS:Linux."
Fabric Port Name: 20:1b:c4:f5:7c:16:a3:a0
Permanent Port Name: 10:00:00:90:fa:c7:d9:37
Device type: Physical Unknown(initiator/target)
Port Index: 27
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 021d00; 3;21:21:00:02:ac:01:21:e0;2f:f7:00:02:ac:01:21:e0; na
FC4s: FCP
PortSymb: [26] "1674208 - 1:2:1 - LPE16002"
NodeSymb: [32] "HP_3PAR 7200 - 1674208 - fw:3223"
Fabric Port Name: 20:1d:c4:f5:7c:16:a3:a0
Permanent Port Name: 21:21:00:02:ac:01:21:e0
Device type: Physical Target
Port Index: 29
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 16G
N 021e00; 3;21:21:00:02:ac:01:9f:21;2f:f7:00:02:ac:01:9f:21; na
FC4s: FCP
PortSymb: [29] "MXN6092BKH - 1:2:1 - LPE32002"
NodeSymb: [36] "HPE_3PAR 8200 - MXN6092BKH - fw:3310"
Fabric Port Name: 20:1e:c4:f5:7c:16:a3:a0
Permanent Port Name: 21:21:00:02:ac:01:9f:21
Device type: Physical Target
Port Index: 30
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 021f00; 3;21:00:00:24:ff:78:5f:19;20:00:00:24:ff:78:5f:19; na
FC4s: NVMe
Fabric Port Name: 20:1f:c4:f5:7c:16:a3:a0
Permanent Port Name: 21:00:00:24:ff:78:5f:19
Device type: Physical Unknown(initiator/target)
Port Index: 31
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 022000; 3;20:03:00:11:0d:c9:cf:00;20:03:00:11:0d:c9:cf:00; na
FC4s: NVMe
PortSymb: [23] "SANBlaze FC Port3 Targ0"
Fabric Port Name: 20:20:c4:f5:7c:16:a3:a0
Permanent Port Name: 20:03:00:11:0d:c9:cf:00
Device type: Physical Unknown(initiator/target)
Port Index: 32
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Slow Drain Device: Yes
Device link speed: 32G
N 022001; 3;20:03:00:11:0d:c9:cf:01;20:03:00:11:0d:c9:cf:01; na
FC4s: FCP
PortSymb: [23] "SANBlaze FC Port3 Targ1"
Fabric Port Name: 20:20:c4:f5:7c:16:a3:a0
Permanent Port Name: 20:03:00:11:0d:c9:cf:00
Device type: NPIV Target
Port Index: 32
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Slow Drain Device: Yes
Device link speed: 32G
N 022400; 3;20:01:00:11:0d:c9:cd:00;20:01:00:11:0d:c9:cd:00; na
FC4s: NVMe
PortSymb: [23] "SANBlaze FC Port1 Targ0"
Fabric Port Name: 20:24:c4:f5:7c:16:a3:a0
Permanent Port Name: 20:01:00:11:0d:c9:cd:00
Device type: Physical Unknown(initiator/target)
Port Index: 36
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
N 022401; 3;20:01:00:11:0d:c9:cd:01;20:01:00:11:0d:c9:cd:01; na
FC4s: FCP
PortSymb: [23] "SANBlaze FC Port1 Targ1"
Fabric Port Name: 20:24:c4:f5:7c:16:a3:a0
Permanent Port Name: 20:01:00:11:0d:c9:cd:00
Device type: NPIV Target
Port Index: 36
Share Area: No
Device Shared in Other AD: No
Redirect: No
Partial: No
LSAN: No
Device link speed: 32G
The Local Name Server has 10 entries }